Access Panel Depth |
Positive <numeric value>
- Sets thickness of guard panel attached along side of vessel.
|
Access Panel Length |
Positive <numeric value>
- Sets length of guard panel attached along side of vessel.
|
Access Panel Width |
Positive <numeric value>
- Sets width of guard panel attached along side of vessel.
|
Air Intake Bottom Offset |
Positive <numeric value>
- Sets the offset between Air Intake connection at End1 and the bottom of equipment.
|
Air Intake Connection Side |
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top
- Puts Air Intake connection on one of the above sides of equipment box.
|
Air Intake Diameter |
Positive <numeric value>
- Sets outside diameter of Air Intake connection of equipment (e.g. Boiler).
|
Air Intake Side Offset |
Positive <numeric value>
- Sets offset between Air Intake connection and side of equipment.
|
Bar Thickness |
Positive <numeric value>
- Sets default thickness of the bars forming grille surface on the equipment (e.g. Catch Basin).
|
Base
|
- Sets or no base at the bottom of vessel (e.g. Air Separator).
|
Base | Height |
Positive <numeric value>
- Sets height of the base attached to vessel bottom. Disabled when No Base is set.
|
Base Inside |
Positive <numeric value>
- Sets distance between the two bars of base of boiler.
|
Base Length |
Positive <numeric value>
- Sets length of base bars, initially matching the length of the boiler.
|
Base To Bottom Of Boiler |
Positive <numeric value>
- Sets distance between base and the bottom of the boiler tube.
|
Body | Height |
Positive <numeric value>
- Sets height of the body, including control box.
|
Body Length |
Positive <numeric value>
- Sets length of the equipment body.
|
Body Width |
Positive <numeric value>
- Sets depth of the equipment body.
|
Boiler Rating |
Positive <numeric value>
- Sets rating of boiler in Btu/Hr in Imperial and kW in Metric unit system.
|
Boiler Type |
- 1-RIRETUBE– for Fire Tube type boiler equipment.
- 2-WATERTUBE– for Water Tube type boiler equipment.
- Sets respective boiler types.
|
Bottom Offset (Outlet) |
Positive <numeric value>
- Sets offset distance between End1 connect point and bottom of equipment.
|
Bottom Offset Outlet1 |
Positive <numeric value>
- Sets vertical offset to Outlet1 connection at End2 from the bottom.
|
Bottom Offset Outlet2 |
Positive <numeric value>
- Sets vertical offset to Outlet2 connection at End3 from the bottom.
|
Box | Height Box | Length
Box | Width |
Positive <numeric value>
- Sets dimensions of sides of equipment box.
|
Brackets Length Brackets Thickness
Brackets Width |
Positive <numeric value>
|
Cell Library |
<cell library file name>
- Library file name for device cells.
For example, Vessel01.
|
Cell Symbol Name |
<cell name>;scale=<numeric value>
- Sets the model cell displayed to the device.
- Scale entry fits cell proportionally to extents of device.
|
Chilled Water In | Bottom Offset |
Positive <numeric value>
- Sets the offset between Chilled Water IN connection at End1 and the bottom of the Chiller unit.
|
Chilled Water In | Connection Side |
- Puts the Chilled Water IN connection at End1 on one of the above sides of Chiller box.
|
Chilled Water In | Diameter |
Positive <numeric value>
- Sets outside diameter of Chilled Water IN connection at End1.
|
Chilled Water In | Side Offset |
Positive <numeric value>
- Sets the offset between Chilled Water IN connection at End1 and the side of the Chiller unit.
|
Chilled Water Out | Bottom Offset |
Positive <numeric value>
- Sets the offset between Chilled Water OUT connection at End2 and the bottom of the Chiller unit.
|
Chilled Water Out | Connection Side |
- Puts the Chilled Water OUT connection at End2 on one of the above sides of Chiller box.
|
Chilled Water out | Diameter |
Positive <numeric value>
- Sets outside diameter of Chilled Water OUT connection at End2.
|
Chilled Water Out | Side Offset |
Positive <numeric value>
- Sets the offset between Chilled Water OUT connection at End2 and the side of the Chiller unit.
|
Coil Length |
Positive <numeric value>
- Sets the straight length of (3)coils at Ends.
|
Cold Water Pipe | Length |
Positive <numeric value>
- Sets distance between End1 and the vessel body.
|
Cold Water Pipe | Outer Diameter |
<numeric value>
- Sets pipe outside diameter for End1 of water heater.
|
Condenser Type |
-
1-Type01
-
2-Type02
-
3-Type03
- Sets condenser type.
- Determines number of compressors; 1 compressor for Type01 and Type02 and 2 for Type03.
Type determines fan and grille positions.
- Type01: Fan at Side | Grille to Left
- Type02: Fan at Top| Grille to Front
- Type03: 2 Fans at Top| Grille to Front
|
Condenser Water IN Bottom Offset
|
Positive <numeric value>
- Sets the offset between Chilled Water IN connection at End5 and the bottom of the Chiller unit.
|
Condenser Water IN Connection Side |
- Puts the Condenser Water IN connection at End5 on one of the above sides of Chiller box.
|
Condenser Water IN Diameter |
Positive <numeric value>
- Sets outside diameter of Chilled Water IN connection at End5.
|
Condenser Water IN Side Offset |
Positive <numeric value>
- Sets the offset between Chilled Water IN connection at End5 and the side of the Chiller unit.
|
Condenser Water OUT Bottom Offset |
Positive <numeric value>
- Sets the offset between Chilled Water OUT connection at End6 and the bottom of the Chiller unit.
|
Condenser Water OUT Connection Side |
- Puts the Condenser Water OUT connection at End6 on one of the above sides of Chiller box.
|
Condenser Water OUT | Diameter |
Positive <numeric value>
- Sets outside diameter of Chilled Water OUT connection at End6.
|
Condenser Water OUT | Side Offset |
Positive <numeric value>
- Sets the offset between Chilled Water OUT connection at End6 and the side of the Chiller unit.
|
Connection 1 | Length (L1) Connection 2 | Length (L2)
Connection 3 | Length (L3) Connection 4 | Length (L4)
Connection 5 | Length (L5) Connection 6 | Length (L6)
|
Positive <numeric value>
- Sets the straight length at:
- End1
- End2
- End3
- End4
- End5
- End6, respectively.
|
Connection1 Outer Diameter Connection2 Outer Diameter
Connection3 Outer Diameter |
Positive <numeric value>
- Sets pipe outside diameters for:
- End1
- End2
- End3, respectively.
|
Connection | End Type |
fl -<numeric value>
- Sets and sizes end with a flange connection.
m -<numeric value>
- Sets and sizes end with a male connection.
fe -<numeric value>
- Sets and sizes end with a female connection.
Separate End Type entries for each End Spec with a semi colon. Example: fl-2;fe-.13 creates a flange at End1 with size 2, and a female connection at End2 with an overall reduction of component's dimensions of .13
|
Connection | Side |
-
1-Back
-
2-Front
-
3-Left
-
4-Right
- Puts connection on one of the above sides of condenser box.
|
Connection Type |
1 - Single Phase
- Sets the electric connection type of boiler to single phase capacity.
2 - 3 Phase
- Sets the electric connection type of boiler to 3 Phase capacity.
|
Control Box Height |
Positive <numeric value>
- Sets height of the control box. Equals 1/10th of Body Height.
|
Control Connection Side |
-
1-Back
-
2-Front
-
3-Left
-
4-Right
- 5-Top– exception Chillers.
- Puts control connection on one of the above sides of equipment box.
|
Control Height Control Length
Control Width |
Positive <numeric value>
- Sets dimensions of sides of control (box) placed on the equipment side.
|
Control Side Offset |
Positive <numeric value>
- Sets offset between control box assembly and side of equipment.
|
Control Top Offset |
Positive <numeric value>
- Sets offset between control box assembly and top of equipment.
|
Depth |
Positive <numeric value>
- Sets depth of vessel cylinder / equipment tank.
|
Diameter |
Positive <numeric value>
- Sets outer diameter of vessel.
|
Dome Height |
Positive <numeric value>
- Sets height of upper surface elevated above the cylinder of vessel.
|
Drain Bottom Offset |
Positive <numeric value>
- Sets offset between control Drain connection and bottom of equipment.
|
Drain Connection Side |
- Puts the Drain connection at End3 on one of the above sides of Chiller box.
|
Drain Diameter Drain | Outer Diameter
|
Positive <numeric value>
- Sets outside diameter of drain connection.
|
Drain Length |
Positive <numeric value>
- Sets the length of the pipe at drain connection.
|
Drain | Side Offset |
Positive <numeric value>
- Sets the offset between Drain connection and side of equipment (e.g. at End3 of Chiller unit.)
|
Drain | Top Offset |
Positive <numeric value>
- Sets the offset between Drain connection and top of equipment.
|
Electrical Coil Connection Diameter |
Positive <numeric value>
- Sets outside diameter of coil connection at End3.
|
Electrical Connection Length |
Positive <numeric value>
- Sets length to straight portion at electric connection at End5.
|
Electrical Connection Width |
Positive <numeric value>
- Sets width to portion at electric connection at End5.
|
Electric Supply Bottom Offset |
Positive <numeric value>
- Sets the offset between Electric Supply connection and the bottom of equipment (e.g. Chiller).
|
Electric Supply Connection Side |
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top
- Puts the Electric Supply connection on one of the above sides of equipment.
|
Electric Supply Diameter |
Positive <numeric value>
- Sets outside diameter of Electric Supply connection in the equipment.
|
Electric Supply Side Offset |
Positive <numeric value>
- Sets the offset between Electric Supply connection and the side of equipment (e.g. Chiller).
|
Electrical Connection Side Offset |
Positive <numeric value>
- Sets offset to End3 connect point from left side on control box.
|
Electrical Connection Top Offset |
Positive <numeric value>
- Sets offset distance between End3 connect point and top of control box.
|
Fan Cylinder Height |
Positive <numeric value>
- Sets height of cylindrical fans placed on Chiller.
|
Fan Diameter |
Positive <numeric value>
- Sets outside diameter of cylindrical fans placed on Chiller.
|
Fan Direction |
1-top
- Puts fan on top of condenser box.
2-side
- Puts fan on side of condenser box.
|
Fan Horizontal Offset |
<numeric value>
- Sets offset to fan from sides.
|
Fan Outer Diameter |
Positive <numeric value>
- Sets outside diameter of fans.
|
Fan Vertical Offset |
<numeric value>
- Sets offset to fan from top, when placed at sides.
|
Flow | Bottom Offset |
Positive <numeric value>
- Sets vertical offset to Flow connection from the bottom.
|
Flow | Connection Side |
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top
- Puts Flow connection at End1 on one of the sides of the equipment.
|
Flow | Diameter |
Positive <numeric value>
- Sets outside diameter of Flow connection at End1 in equipment.
|
Flow | Side Offset |
Positive <numeric value>
- Sets horizontal offset to Flow connection from the side.
|
Flue Connection Side |
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top
- Puts Flue connection on one of the above sides of boiler equipment box.
|
Flue Diameter |
Positive <numeric value>
- Sets outside diameter of Flue connection at End5 in Boiler equipment.
|
Flue Front Offset |
Positive <numeric value>
- Sets horizontal offset to Flue connection from the side of equipment.
|
Flue Side Offset |
Positive <numeric value>
- Sets horizontal offset to Flue connection from the bottom of equipment.
|
Fuel Flow Rate |
<numeric value>
- Sets a value for the amount of fuel flow through the equipment, in GpM in Imperial and l/s in Metric unit system. Used to calculate overall flow rate during analysis operations.
|
Fuel Type |
- Puts fan on top of condenser box.
- Puts fan on side of condenser box.
|
Gas Inlet | Bottom Offset |
Positive <numeric value>
- Sets horizontal offset to Gas Inlet connection from the bottom.
|
Gas Inlet | Connection Side |
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top
- Puts Gas Inlet connection on one of the above sides of boiler equipment box.
|
Gas Inlet | Diameter |
Positive <numeric value>
- Sets outside diameter to Gas Inlet connection.
|
Gas Inlet | Side Offset |
Positive <numeric value>
- Sets horizontal offset to Gas Inlet connection from the side.
|
Grille Depth |
Positive <numeric value>
- Sets depth of grille portion.
|
Grille Offset Horizontal |
<numeric value>
- Sets offset to grille portion from right side. Negative offset shifts grille to the right. 0 offset aligns grille portion in the center of panel.
|
Grille Offset Vertical |
<numeric value>
- Sets offset to grille portion from bottom side. Negative offset shifts grille down.
|
Grille Width |
Positive <numeric value>
- Sets width of grille portion.
|
Height |
Positive <numeric value>
- Sets straight height of vessel cylinder / equipment tank.
|
Hot Water Pipe | Length |
Positive <numeric value>
- Sets distance between End1 and the vessel body.
|
Hot Water Pipe | Outer Diameter |
<numeric value>
- Sets pipe outside diameter for End2 of water heater.
|
Inlet | Connection Side Outlet 1 | Connection Side
Outlet 2 | Connection Side |
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top
-
6-Bottom
- Puts the respective inlet / outlet connection on one of the above sides of equipment box.
|
Inlet | Length |
Positive <numeric value>
- Sets length of Inlet pipe at End1, in addition to Connection1 Length.
|
Inlet | Outer Diameter |
Positive <numeric value>
- Sets outer diameter of the inlet connection (End1) of the equipment.
|
Inlet |
Positive <numeric value>
- Sets horizontal offset to Inlet connection from side of equipment.
|
Inlet | Top Offset |
Positive <numeric value>
- Sets vertical offset to Inlet connection from top of equipment.
|
Inlet/Outlet | Top Offset |
Positive <numeric value>
- Sets straight height between center of End1/End2 and top of the equipment, equals default half of total height, and can be set higher
|
Length |
Positive <numeric value>
- Sets straight length of vessel cylinder / equipment tank.
|
Liquid Coil | Outer Diameter |
Positive <numeric value>
- Sets outside diameter D1 of coil connection at End1.
|
Liquid Coil | Side Offset |
Positive <numeric value>
- Sets offset to End1 connect point from right side on control box.
|
Liquid Coil | Top Offset |
Positive <numeric value>
- Sets offset distance between End1 connect point and top of control box.
|
Material |
-
1-Steel
-
2-Concrete
-
3-GRP
-
4-Polyethene
-
5-Fiberglass
- Sets the storage tank body material.
|
Mount Type |
- 1-Vertical - mounts vessel vertical.
- 2-Horizontal - mounts vessel horizontal.
- Sets the mounting orientation to the vessel.
|
No. of Compressor |
- Sets the number of compressor units in condenser.
Condenser Type determines compressor count.
- Type01 /Type02: 1 Compressor.
- Type03 : 2 Compressors.
|
Number Of Air Vents |
- Sets number of air vents on the vent assembly on the top of Air Separator.
|
Number Of Fans |
<integer>
- Sets number of fan in the equipment.
|
No. Of Horizontal Bars |
<integer>
- Sets number of horizontal bars.
|
Number Of Strips |
<numeric value>
- Sets number of strips on the side of round Catch Basin.
|
No. Of Vertical Bars |
<integer>
- Sets number of vertical bars.
|
Offset Between Two Fans |
<numeric value>
- Sets offset between center of fans (for Type03).
|
Outlet 1 | Length |
Positive <numeric value>
- Sets length of outlet pipe at End2, in addition to Length 2.
|
Outlet 2 | Length |
Positive <numeric value>
- Sets length of additional outlet pipe at End3, in addition to Length 3.
|
Outlet | Diameter |
Positive <numeric value>
- Sets outside diameter of connection at End1.
|
Outlet | Diameter |
Positive <numeric value>
- Sets diameter of outlet pipe at End2.
- Sets outside diameter of outlet connection at End1. (for Catch Basin)
|
Outlet | Length |
Positive <numeric value>
- Sets length of outlet pipe.
|
Pot Diameter |
Positive <numeric value>
- Sets outside diameter of body of Dosing Pot equipment.
|
Pot Length |
Positive <numeric value>
- Sets body length of Dosing Pot equipment.
|
Return | Bottom Offset |
Positive <numeric value>
- Sets offset to Return connection at End2 from bottom of equipment.
|
Return | Connection Side |
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top
- Puts Return connection at End2 on one of the sides of the equipment.
|
Return | Diameter |
Positive <numeric value>
- Sets outside diameter of Return connection at End2 of equipment.
|
Return | Side Offset |
Positive <numeric value>
- Sets offset to Return connection at End2 from side of equipment.
|
Section Height Section Length
Section Width |
Positive <numeric value>
- Sets dimensions of the tank (when TankType is set Sectional).
|
Shell Inlet | Connection Side |
-
1-Top
-
2-Bottom
-
3-Front
-
4-Back
- Puts shell inlet connection on one of the sides of the equipment.
|
Shell Inlet | Diameter |
Positive <numeric value>
- Sets outside diameter of shell inlet connection of Heat Exchanger at End3.
|
Shell Inlet | Length |
Positive <numeric value>
- Sets length of shell inlet connection of Heat Exchanger at End3.
|
Shell Inlet | Offset |
Positive <numeric value>
- Sets horizontal offset distance of inlet connect point at End3 to the left of the side of heat exchanger.
|
Shell Outlet | Connection Side |
-
1-Top
-
2-Bottom
-
3-Front
-
4-Back
- Puts shell outlet connection on one of the sides of the equipment.
|
Shell Outlet | Diameter |
Positive <numeric value>
- Sets outside diameter of shell outlet connection of Heat Exchanger at End4.
|
Shell Outlet | Length |
Positive <numeric value>
- Sets length of shell outlet connection of Heat Exchanger at End4.
|
Shell Outlet | Offset |
Positive <numeric value>
- Sets horizontal offset distance of outlet connect point at End4 to the left of the side of heat exchanger.
|
Inlet | Side Offset |
Positive <numeric value>
- Sets horizontal offset to Inlet connection at End1 from the side.
|
Outlet 1 | Side Offset |
Positive <numeric value>
- Sets horizontal offset to Outlet1 connection at End2 from the side.
|
Outlet 2 | Side Offset |
Positive <numeric value>
- Sets horizontal offset to Outlet2 connection at End3 from the side.
|
Stand Height |
Positive <numeric value>
- Sets height to the stand attached to the vessel body of Shell and Tube heat exchanger equipment.
|
Stand Width |
Positive <numeric value>
- Sets width to the stand attached to the vessel body of Shell and Tube heat exchanger equipment.
The length of stand is set internally proportionally with the vessel diameter. |
Strip Thickness |
Positive <numeric value>
- Sets default thickness to strips forming grille surface on the equipment (e.g. Catch Basin).
|
Suction Coil Side Offset |
Positive <numeric value>
- Sets offset to End2 connect point from right side on control box.
|
Suction Coil Top Offset |
Positive <numeric value>
- Sets offset distance between End2 connect point and top of control box.
|
Suction Coil Outer Diameter |
Positive <numeric value>
- Sets outside diameter D2 of coil connection at End3.
|
Tag |
<alpha-numeric characters>
- Sets tag value visible in output of drawing composition in dynamic view. Separate tag strings with a semi colon.
Default tag is OutDoor Condenser. |
Tank Height Tank Length
Tank Width |
Positive <numeric value>
- Sets dimensions of sides of tank. Modified using the Section dimensions.
|
Tank Type |
|
Inlet | Top Offset |
Positive <numeric value>
- Sets offset distance between End2 connect point and top of equipment.
|
Inlet | Top Offset |
Positive <numeric value>
- Sets vertical offset to Inlet connection at End1 from the side.
|
Total Length |
Positive <numeric value>
- Sets distance between End1 and End2 of equipment.
|
Total Height |
<Positive numeric value>
- Sets the height from the base to the discharge port/manifold end 2 surface.
- Sets straight height from End3 connection at bottom to the vent at top, equals default twice the Height1.
|
Tube Connection Side |
- Sets tube inlet and outlet connections to either Left or Right side of unit.
|
Tube Inlet | Diameter |
Positive <numeric value>
- Sets outside diameter of tube inlet connection of Heat Exchanger at End1.
|
Tube Inlet | Length |
Positive <numeric value>
- Sets length of shell inlet connection of Heat Exchanger at End1.
|
Tube Inlet | Offset |
Positive <numeric value>
- Sets horizontal offset distance of inlet connect point at End1 to the center of the side of heat exchanger the inlet is connected.
|
Tube Outlet | Diameter |
Positive <numeric value>
- Sets outside diameter of tube outlet connection of Heat Exchanger at End2.
|
Tube Outlet | Length |
Positive <numeric value>
- Sets length of shell outlet connection of Heat Exchanger at End2.
|
Tube Outlet | Offset |
Positive <numeric value>
- Sets horizontal offset distance of outlet connect point at End2 to the center of the side of heat exchanger the outlet is connected.
|
Tundish Diameter |
Positive <numeric value>
- Sets outside diameter of body of Tundish equipment.
|
Tundish Length |
Positive <numeric value>
- Sets body length of Tundish equipment.
|
Vent Assembly Diameter |
Positive <numeric value>
- Sets outside diameter of vent assembly housing the air vents on the top of equipment.
|
Wall Thickness |
Positive <numeric value>
- Sets thickness of walls of tank unit.
|
Width |
Positive <numeric value>
- Sets width of equipment tank /vessel cylinder.
|